5,193 research outputs found

    Patients' practices and experiences of using nebuliser therapy in the management of COPD at home.

    Get PDF
    How patients use their nebulisers at home is vital to ensure effective treatment and optimal health outcomes for patients with chronic obstructive pulmonary disease (COPD). The aim of the study was to identify the practicalities and problems associated with nebuliser use by patients with COPD at home, which may impact on the safety and effectiveness of therapy

    Meta-analysis: the diagnostic accuracy of critical flicker frequency in minimal hepatic encephalopathy

    Get PDF
    BACKGROUND: Minimal hepatic encephalopathy (MHE) reduces quality of life, increases the risk of road traffic incidents and predicts progression to overt hepatic encephalopathy and death. Current psychometry-based diagnostic methods are effective, but time-consuming and a universal ‘gold standard’ test has yet to be agreed upon. Critical Flicker Frequency (CFF) is a proposed language-independent diagnostic tool for MHE, but its accuracy has yet to be confirmed. AIM: To assess the diagnostic accuracy of CFF for MHE by performing a systematic review and meta-analysis of all studies, which report on the diagnostic accuracy of this test. METHODS: A systematic literature search was performed to locate all publications reporting on the diagnostic accuracy of CFF for MHE. Data were extracted from 2 × 2 tables or calculated from reported accuracy data. Collated data were meta-analysed for sensitivity, specificity, diagnostic odds ratio (DOR) and summary receiver operator curve (sROC) analysis. Prespecified subgroup analysis and meta-regression were also performed. RESULTS: Nine studies with data for 622 patients were included. Summary sensitivity was 61% (95% CI: 55–67), specificity 79% (95% CI: 75–83) and DOR 10.9 (95% CI: 4.2–28.3). A symmetrical sROC gave an area under the receiver operator curve of 0.84 (SE = 0.06). The heterogeneity of the DOR was 74%. CONCLUSIONS: Critical Flicker Frequency has a high specificity and moderate sensitivity for diagnosing minimal hepatic encephalopathy. Given the advantages of language independence and being both simple to perform and interpret, we suggest the use of critical flicker frequency as an adjunct (but not replacement) to psychometric testing

    Patients' management of type 2 diabetes in Middle Eastern countries: review of studies

    Get PDF
    The increased prevalence of diabetes in Middle Eastern countries is a health policy priority. Important risk factors for diabetes have been identified. Lifestyle interventions and adherence to medications are central to disease prevention and management. This review focuses on the management of type 2 diabetes mellitus in Middle Eastern countries. The aim is to identify the ways in which knowledge, health beliefs, and social and cultural factors influence adherence to medication and lifestyle measures. Thirty-four studies were identified following a systematic search of the literature. The studies describe the influence of knowledge, health beliefs, culture, and lifestyle on the management of type 2 diabetes mellitus in the Middle East. Findings indicate a lack of health knowledge about diabetes among populations, which has implications for health behaviors, medication adherence, and treatment outcomes. Many identified health beliefs and cultural lifestyle factors, such as religious beliefs, beliefs about fasting during Ramadan, and sedentary lifestyles played a role in patients’ decisions. For better management of this disease, a collaborative approach between patients, their families, health care professionals, and governments should be adopted. Implementing behavioral strategies and psychological interventions that incorporate all health care professionals in the management process have been shown to be effective methods. Such services help patients change their behavior. However, the utilization of such services and interventions is still limited in Arabian countries. Physicians in the Middle East are the health care professionals most involved in the care process

    Histiocytoid cardiomyopathy and microphthalmia with linear skin defects syndrome: phenotypes linked by truncating variants in NDUFB11

    Get PDF
    Variants in NDUFB11, which encodes a structural component of complex I of the mitochondrial respiratory chain (MRC), were recently independently reported to cause histiocytoid cardiomyopathy (histiocytoid CM) and microphthalmia with linear skin defects syndrome (MLS syndrome). Here we report an additional case of histiocytoid CM, which carries a de novo nonsense variant in NDUFB11 (ENST00000276062.8: c.262C > T; p.[Arg88*]) identified using whole-exome sequencing (WES) of a family trio. An identical variant has been previously reported in association with MLS syndrome. The case we describe here lacked the diagnostic features of MLS syndrome, but a detailed clinical comparison of the two cases revealed significant phenotypic overlap. Heterozygous variants in HCCS (which encodes an important mitochondrially targeted protein) and COX7B, which, like NDUFB11, encodes a protein of the MRC, have also previously been identified in MLS syndrome including a case with features of both MLS syndrome and histiocytoid CM. However, a systematic review of WES data from previously published histiocytoid CM cases, alongside four additional cases presented here for the first time, did not identify any variants in these genes. We conclude that NDUFB11 variants play a role in the pathogenesis of both histiocytoid CM and MLS and that these disorders are allelic (genetically related)

    Elevated Intraocular Pressure After Intravitreal Steroid Injection in Diabetic Macular Edema: Monitoring and Management

    Get PDF
    INTRODUCTION: With the increasing use of intravitreal administration of corticosteroids in macular edema, steroid-induced intraocular pressure (IOP) rise is becoming an emergent issue. However, for patients in whom intravitreal steroids are indicated, there are no specific recommendations for IOP monitoring and management after intravitreal administration of corticosteroids. METHOD: An expert panel of European ophthalmologists reviewed evidence on corticosteroid-induced IOP elevation. The objective of the panel was to propose an algorithm based on available literature and their own experience for the monitoring and management of corticosteroid-induced IOP elevation, with a focus on diabetic patients. RESULTS: Data from trials including diabetic patients with a rise of IOP after intravitreal steroid administration indicate that IOP-lowering medical treatment is sufficient for a large majority of patients; only a small percentage underwent laser trabeculoplasty or filtering filtration surgery. A 2-step algorithm is proposed that is based on the basal value of IOP and evidence for glaucoma. The first step is a risk stratification before treatment. Patients normotensive at baseline (IOP ≤ 21 mmHg), do not require additional baseline diagnostic tests. However, patients with baseline ocular hypertension (OHT) (IOP > 21 mmHg) should undergo baseline imaging and visual field testing. The second step describes monitoring and treatment after steroid administration. During follow-up, patients developing OHT should have baseline and periodical imaging and visual field testing; IOP-lowering treatment is proposed only if IOP is >25 mmHg or if diagnostic tests suggest developing glaucoma. CONCLUSION: The management and follow-up of OHT following intravitreal corticosteroid injection is similar to that of primary OHT. If OHT develops, IOP is controlled in a large proportion of patients with standard IOP treatments. The present algorithm was developed to assist ophthalmologists with guiding principles in the management of corticosteroid-induced IOP elevation. FUNDING: Alimera Sciences Limited

    Assistance of family carers for patients with COPD using nebulisers at home: a qualitative study

    Get PDF
    Objective: For many patients with chronic conditions, such as chronic obstructive pulmonary disease (COPD), the assistance of family carers with medicines is vital for optimal treatment outcomes. The aim of this study was to identify the assistance carers provide to patients with COPD using nebuliser-delivered therapy at home, and the problems experienced that may impact on the safety and effectiveness of therapy and contribute to carer burden. Methods: A cross-sectional, qualitative descriptive study was conducted with participants recruited from primary and intermediate care. Home interviews were conducted with 14 carers who assisted a family member with COPD using a nebuliser. Qualitative procedures enabled analysis of nebuliser-related activities and problems experienced by carers. Results: The carer sample included 10 female and 4 male carers, with a mean age of 61 years: 11 spouses and 3 daughters. They had assisted patients with use of their nebuliser and associated medications for, on average, 4.5 years. Assistance ranged from taking full responsibility for nebuliser use to providing help with particular aspects only when required. Nebuliser-related activities included assembling and setting up equipment, mixing medicines, operating the device, dismantling and cleaning equipment. Difficulties were described with all aspects of care. Carers reported concerns about medication side effects and the lack of information provided. Conclusions: The study revealed the vital role of carers in enabling effective therapy. The wide-ranging responsibilities assumed by carers and problems experienced relate to all aspects of COPD management with nebulisers, and have a potential impact on treatment outcomes and carer burden. A systematic approach to addressing carers' needs and prioritising support would be anticipated to have positive consequences for patients, carers and health services

    Splines and Wavelets on Geophysically Relevant Manifolds

    Full text link
    Analysis on the unit sphere S2\mathbb{S}^{2} found many applications in seismology, weather prediction, astrophysics, signal analysis, crystallography, computer vision, computerized tomography, neuroscience, and statistics. In the last two decades, the importance of these and other applications triggered the development of various tools such as splines and wavelet bases suitable for the unit spheres S2\mathbb{S}^{2},   S3\>\>\mathbb{S}^{3} and the rotation group SO(3)SO(3). Present paper is a summary of some of results of the author and his collaborators on generalized (average) variational splines and localized frames (wavelets) on compact Riemannian manifolds. The results are illustrated by applications to Radon-type transforms on Sd\mathbb{S}^{d} and SO(3)SO(3).Comment: The final publication is available at http://www.springerlink.co

    Are there associations with age and sex in walking stability in healthy older adults?

    Get PDF
    The variability of the centre of pressure (COP) during walking can provide information in relation to stability when walking. The aim of this study was to investigate if age and sex were associated with COP variability, COP excursions, and COP velocities during walking. One-hundred and fourteen older adults (age 65.1 ± 5.5 yrs.) participated in the study. A Kistler force platform (1000 Hz) recorded the ground reaction forces and COPs during walking at a self-selected walking speed. The stance phase was divided, using the vertical GRF, into four sub-phases: loading response (LR), mid-stance (MSt), terminal stance (TSt), and pre-swing (PSw). The standard deviations of the COP displacement (variability), the COP velocity, and COP excursion in the medial–lateral and anterior–posterior directions, as well as the resultant magnitude were assessed. When controlling for walking speed, a greater age was associated with a higher variability and excursion of the COP during LR only suggesting that stability is maintained during the majority of the stance phase. During LR lower COP velocity was significantly associated for females for anterior-posterior and total COP, which may be a strategy to facilitate stability before, and moving into, MSt and TSt

    Using computer-aided detection in mammography as a decision support

    Get PDF
    Contains fulltext : 87548.pdf (publisher's version ) (Closed access)OBJECTIVE: To evaluate an interactive computer-aided detection (CAD) system for reading mammograms to improve decision making. METHODS: A dedicated mammographic workstation has been developed in which readers can probe image locations for the presence of CAD information. If present, CAD findings are displayed with the computed malignancy rating. A reader study was conducted in which four screening radiologists and five non-radiologists participated to study the effect of this system on detection performance. The participants read 120 cases of which 40 cases had a malignant mass that was missed at the original screening. The readers read each mammogram both with and without CAD in separate sessions. Each reader reported localized findings and assigned a malignancy score per finding. Mean sensitivity was computed in an interval of false-positive fractions less than 10%. RESULTS: Mean sensitivity was 25.1% in the sessions without CAD and 34.8% in the CAD-assisted sessions. The increase in detection performance was significant (p = 0.012). Average reading time was 84.7 +/- 61.5 s/case in the unaided sessions and was not significantly higher when interactive CAD was used (85.9 +/- 57.8 s/case). CONCLUSION: Interactive use of CAD in mammography may be more effective than traditional CAD for improving mass detection without affecting reading time.1 oktober 201
    • …
    corecore